Home About Us Services ↳ Canada PR Visa (Permanent Residency) ↳ Work Permit Canada ↳ LMIA — Labour Market Impact Assessment ↳ Spouse & Family Sponsorship Visa ↳ Student Visa Canada ↳ Visitor Visa ↳ Business Visa Provinces ↳ 🏙️ Ontario ↳ 🏔️ British Columbia ↳ 🌾 Alberta ↳ 🌻 Saskatchewan ↳ 🌊 Manitoba ↳ ⚓ Nova Scotia ↳ 🍁 New Brunswick ↳ 🦞 Prince Edward Island ↳ 🐟 Newfoundland & Labrador ↳ 🌊 Atlantic Immigration Program Healthcare Blog FAQ Careers Canadian Latest policies Contact

Wood preservation facilities, pentachlorophenol pressure: chapter E, table 23


Table 23. Recommended Disposal Practices for PCP-Contaminated Wastes

(Use in conjunction with Part I, Chapter A - General Recommendations for All Wood Preservatives, Table 23.)

Waste category Examples Recommendations
Liquid PCP/oil solutions
  • Spilled PCP/oil concentrates
  • PCP work solutions
  • Drips from freshly treated lumber
  • Material skimmed from oil separators
  • Collect and reuse.
Liquid PCP/water solutions
  • Condensates
  • Washwaters
  • Infiltrating waters
  • Treat to remove oil and PCP to within regulatory limits.
  • Dispose of treated waters as per regulatory requirements.
Contaminated solid wastes
  • Debris and bottom sludge from storage tanks, sumps and pressure cylinders
  • Soils contaminated by spills
  • Cleanup absorbents
  • Filter from cleaning vacuum
  • Sludges from wastewater treatment processes
  • Solid fire residues from PCP or PCP/oil storage areas
  • Wrapping used for PCP blocks
  • Scraps, cuttings and shavings from PCP-treated lumber
  • Drain and/or drum, store and dispose of in accordance with provincial regulatory requirements (high-temperature thermal destruction at authorized facilities appears to be the most feasible disposal option).
Miscellaneous solid wastes
  • Empty containers and wrapping rinsed with alkaline water
  • Dispose of in authorized sanitary landfills (subject to approval by the provincial regulatory agency).
  • Recuperated by authorized facilities.
Contaminated storm runoff
  • Storm runoff or contaminated liquid discharges containing PCP requires consultation with regulatory agency.
  • Prevent or minimize contamination of storm runoff to greatest possible extent.
  • Monitor surface water discharges (in consultation with the provincial regulatory agency) to assess contaminant concentrations and determine the need for control.
  • Provide mean for collection of contaminated storm runoff.
Firefighting water runoff
  • As above (contaminated storm runoff)
  • Consider provisions for containment where PCP and PCP/oil solutions are present.
  • Consult with provincial regulatory agency to determine acceptable disposal practices.

Page details

2017-09-10

Quick Enquiry

We usually reply within a few hours
By submitting you agree to be contacted about your enquiry.
Call us Chat on WhatsApp
M

Migova AI Assistant

Online now
Hi 👋 I'm the Migova AI assistant, powered by OpenAI. Ask me about PR, study visas, work permits, LMIA, family sponsorship, provinces, or healthcare immigration to Canada.
Canada PR
Study Visa
LMIA / Work Permit